GIM500R - 2-dimensional - Inclination sensor
Technical data - electrical ratings | |
---|---|
Voltage supply | 8...36 VDC |
Reverse polarity protection | Yes |
Short-circuit proof | Yes |
Consumption w/o load | ≤40 mA (24 VDC) |
Initializing time | ≤0.5 s after power on |
Interface | CANopen® SAE J1939 Analog (4...20 mA, 0...5 V or 0...10 V) |
Measuring range | ±10°/±30°/±45°/±60°/±90° |
Load resistor | ≥1 k? / voltage output ≤800 ? / current output |
Resolution | 0.025 ° |
Accuracy (+25 °C) | Typ. ±0.1° |
Temperature coefficient | 0.009 °/K (0...36 °C) 0.008 °/K (36...90 °C) |
Cross-axis-sensitivity typ. | 0.3 % |
Repeatability | 0.1 ° (+25 °C) |
Sensing rate | 800 Hz |
Limit frequency | 0.1...25 Hz, 2. order / low-pass filter (Default: 5 Hz) |
Interference immunity | DIN EN 61000-6-2 ECE Reg. No. 10R04 ISO 7637-2 ISO 11452-2 / ISO 11452-5 |
Emitted interference | DIN EN 61000-6-4 ECE Reg. No. 10R04 ISO 7637-2 / EN 55025 |
Programmable parameters |
Preset and offset Filter |
Diagnostic function | Parameter error |
Status indicator | DUO-LED integrated in housing |
Approval | UL approval / E63076 |
Technical data - mechanical design | |
Dimensions W x H x L | 48 x 24 x 52 mm |
Protection DIN EN 60529 | IP 66 IP 67 IP 68 IP 69K |
Material | Housing: aluminium, coated |
Corrosion protection | IEC 60068-2-52 Salt mist Complies to ISO 12944-5:1998 Protective paint systems (C5-M) |
Operating temperature | -40...+85 °C (see general information) |
Resistance | DIN EN 60068-2-6 Vibration ±1.5 mm - 10-58 Hz 20 g - 58-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms |
Weight approx. | 95 g |
Connection | Flange connector M12, 8-pin Flange connector M12, 5-pin Cable 1 m |