Technical data - electrical ratings | |
---|---|
Voltage supply | 10...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤100 mA (24 VDC) |
Initializing time typ. | 250 ms after power on |
Interface | CANopen® Profibus-DPV0 |
Device adress | Rotary switches in bus cover |
Measuring range | ±15°/±30°/±60° (two-dimensional) 360° (one-dimensional) |
Resolution | 0.001..1 ° (measuring range 15°, 30°, 60°) 0.1..1 ° (measuring range 360°) |
Accuracy (+25 °C) | ±0.1° (measuring range 15°) ±0.2° (measuring range 30°, 60°, 360°) |
Settling time max. | 0.5 s |
Measuring cycle | 10 Hz |
Code | Binary |
Interference immunity | DIN EN 61000-6-2 |
Emitted interference | DIN EN 61000-6-4 |
Programmable parameters |
Resolution Preset and offset |
Diagnostic function | Parameter error |
Status indicator | DUO-LED integrated in bus cover |
Approval | UL approval / E63076 |
Technical data - mechanical design | |
Dimensions mounting plate | 99 x 60 x 5 mm |
Protection DIN EN 60529 | IP 66 (connector M12) IP 67 (cable gland) |
Material | Bus cover: zinc die-cast Base plate: aluminium |
Operating temperature | -25...+85 °C -40...+85 °C (optional: only cable gland) |
Relative humidity | 95 % non-condensing |
Resistance | DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms |
Weight approx. | 250 g |
Connection | Cable gland Connector M12, 4-pin Connector M12, 5-pin |